Initial project import
This commit is contained in:
@@ -1,7 +1,8 @@
|
||||
# 1C Agent Coding Contract
|
||||
|
||||
This contract is the default rule set for coding agents that work through the
|
||||
1C adapter.
|
||||
1C adapter. The agent calls it only through the `onec_request` MCP tool; the
|
||||
REST SQL adapter is MCP's private downstream transport.
|
||||
|
||||
## Default View
|
||||
|
||||
@@ -13,6 +14,57 @@ This contract is the default rule set for coding agents that work through the
|
||||
- Objects can exist only in saved-state and can later be activated or canceled.
|
||||
Do not hide them from the agent view.
|
||||
|
||||
### Empty saved-state layer
|
||||
|
||||
An empty saved-state layer is normal before the first edit. In that case an
|
||||
agent still uses only public selectors and reports the adapter result; it must
|
||||
not obtain an active `ConfigCAS`/`Config` module reference and retry by hand.
|
||||
|
||||
Known adapter limitation (2026-08-02): for an extension-owned object module
|
||||
with no prepared saved-state row, public `code.read` can return
|
||||
`source_missing` even though the active module is proven to exist. Treat this
|
||||
as an adapter defect, not as evidence that the 1C object or BSL is absent.
|
||||
Use a developer-owned diagnostic check to investigate it; do not expose its
|
||||
storage coordinates to a coding agent.
|
||||
|
||||
## Required adapter acceptance fixture
|
||||
|
||||
`upo_test` must contain one isolated extension-owned `Report` with a decoded
|
||||
`object_module`, a unique BSL anchor, and no shared business role. This fixture
|
||||
is created and maintained by a human in Configurator; the SQL-only adapter must
|
||||
not fabricate it. It is the required target for the public acceptance sequence:
|
||||
|
||||
```text
|
||||
code.read(ref, extension, module_ordinal=1)
|
||||
→ code.write(old, new, apply_and_rollback)
|
||||
→ code.search verifies new text
|
||||
→ rollback and saved-state cleanup
|
||||
```
|
||||
|
||||
The request must contain no `layer`, table, file name, module ref, payload hash,
|
||||
or stream index. Until the fixture exists, unit tests prove routing only; they
|
||||
do not prove a live extension Report write.
|
||||
|
||||
### Verified base-module smoke
|
||||
|
||||
On 2026-08-02 the public sequence was verified on `upo_test` against base
|
||||
`Report.АвтоматическиеСкидки`, `module_ordinal=1`: a unique comment replacement
|
||||
completed in about 25 seconds with `verified_and_rolled_back`. The adapter
|
||||
auto-prepared `ConfigSave`, read back the write, rolled back the BSL change,
|
||||
then removed the exact rows it had prepared. The public result contains the
|
||||
opaque `prepare_receipt_id` and `prepare_cleanup`; the final saved-state status
|
||||
was `empty`. This validates the base route only, not the extension Report route.
|
||||
Live check on 2026-08-02 found 19 extensions but zero extension-owned Reports
|
||||
in `upo_test`; therefore the required extension acceptance fixture is currently
|
||||
missing and the extension write branch remains unaccepted.
|
||||
|
||||
Live check on 2026-08-13 found an extension BSL stream for
|
||||
`Report.УОП_ИнвентаризационнаяОпись`, but its `role_status=unconfirmed`.
|
||||
That is read-only evidence, not an acceptance fixture: do not write through an
|
||||
ordinal, storage reference, or guessed Configurator role. A human must add or
|
||||
identify one extension Report with a decoded `object_module` before the live
|
||||
extension `apply_and_rollback` test can run.
|
||||
|
||||
## Compare Views
|
||||
|
||||
- Use `state=both` or `source_state=all` only when the task needs a comparison
|
||||
@@ -33,6 +85,34 @@ Use public names and selectors:
|
||||
3. `code.read` with `state=working` to read the module or routine.
|
||||
4. `code.read` with `state=both` only for an explicit saved-vs-active check.
|
||||
|
||||
For a report form, keep the descriptions separate:
|
||||
|
||||
1. `metadata.object.forms(ref=Report.<name>, source_state=working)` lists the
|
||||
report's form references.
|
||||
2. `metadata.object.form.details` with that same public report ref and the
|
||||
returned form name reads the form description (attributes, parameters,
|
||||
commands, items, and the form module).
|
||||
3. `metadata.form.decode(view=structure)` is an optional compact static
|
||||
projection. It must retain `unresolved` parent/child links where no SQL
|
||||
codec has proved them.
|
||||
|
||||
A form command does not have its own module. Its handler is a named routine in
|
||||
the form module only when the decoder returns an evidenced command link.
|
||||
|
||||
Use the `read_selector.selector_token` returned by discovery with the method
|
||||
declared in that selector. Do not copy GUIDs, module refs, table names, or file
|
||||
names into a follow-up request. A module ordinal, display name, or storage-derived role
|
||||
is not a Configurator-tree path. If a result has `role_status=unconfirmed` or
|
||||
`configurator_path_status=unconfirmed`, the agent must not name, write, or
|
||||
infer its tree owner; report the missing decoder evidence instead.
|
||||
|
||||
When checking object commands, call `metadata.object.commands` with the same
|
||||
public `ref`/`kind`+`name` and `extension` selector. The adapter resolves the
|
||||
extension name and reads its active metadata itself. A prior `not_found` from a
|
||||
route that did not carry the extension context is not evidence that the report
|
||||
has no commands. Conversely, a BSL stream suffix alone is never evidence of a
|
||||
command or of its module path.
|
||||
|
||||
Agents should ask for and report object names, routine names, and code text.
|
||||
They should not ask users for SQL tables, storage file names, stream indexes, or
|
||||
saved-state write flags during normal coding work.
|
||||
@@ -52,12 +132,52 @@ Supported public edit shapes:
|
||||
say "save this code" and send the desired code text. It must not ask whether SQL
|
||||
saved-state apply flags are allowed.
|
||||
|
||||
For extension object modules, preparation maps the active payload route to its
|
||||
canonical saved-state filename internally. A public `code.write` therefore
|
||||
continues with `extension`, `ref`, module role, and the proven replacement
|
||||
only; it must never ask the caller to supply the canonical filename or stream.
|
||||
|
||||
Every successful `code.write` response must show:
|
||||
|
||||
- `write_mode.target=saved_state`;
|
||||
- `write_mode.activation_state=not_activated`;
|
||||
- `write_mode.production_apply=false`.
|
||||
|
||||
### Repository-controlled extension writes
|
||||
|
||||
For a repository-controlled extension, use the public sequence below and stop
|
||||
when it asks for a human Configurator action:
|
||||
|
||||
```text
|
||||
code.search(extension, ref, old fragment)
|
||||
→ repository.lock.plan(extension, ref)
|
||||
→ repository.lock.request
|
||||
→ human captures the exact object in Configurator
|
||||
→ repository.lock.confirm
|
||||
→ code.write(extension, ref, module_ordinal, old, new, repository_lock)
|
||||
→ code.search readback
|
||||
```
|
||||
|
||||
The lock plan for `upo / фс_Отчеты1 /
|
||||
Report.фс_ПродовольственнаяКорзина` resolves exactly one object:
|
||||
`Отчет.фс_ПродовольственнаяКорзина`, in extension layer
|
||||
`extension:8e02accd-8a34-11f1-8294-005056b0d483`. SQL cannot prove a native
|
||||
Configurator capture; only a human confirmation can continue this route.
|
||||
|
||||
`metadata.write.preflight` currently plans canonical high-level
|
||||
`metadata.write` targets and may return `needs_route` for this compatibility
|
||||
`code.write` shape before saved-state preparation. This is not permission to
|
||||
use its low-level payload hint. Use `code.write(mode=plan)` instead: a first
|
||||
extension edit may return public `needs_prepare`, which means to confirm the
|
||||
repository lock and reissue the same public request in an apply mode. Keep
|
||||
using the public `code.write` route; report any different route failure to
|
||||
adapter developers.
|
||||
|
||||
If it returns `extension_saved_state_prepare_protocol_unproven`, do not retry
|
||||
or supply technical coordinates. The adapter has not yet proven the exact
|
||||
saved-state preparation codec for this extension layout; report it for adapter
|
||||
development. Do not infer that the extension was not saved in Configurator.
|
||||
|
||||
## Hidden Storage Details
|
||||
|
||||
The form module container marker `///----` is adapter-owned storage syntax.
|
||||
|
||||
Reference in New Issue
Block a user