Known dead ends and prohibited shortcuts

Do not repeat

  • Do not write only a module .0 row: __configinfo then references stale bytes and activation fails.
  • Do not use random, zeroed, copied-from-unrelated, or guessed HashVersion service atoms. A controlled random test produced a licensing/crypto error.
  • Do not write Config or ConfigCAS directly, even in tests.
  • Do not use a suffix such as .0 as proof of “object module”.
  • Do not infer an object name from a GUI tree label, table suffix, or an approximate Russian name.
  • Do not overwrite all saved-state rows when adding a delta: preserve user work in other objects and every map entry.
  • Do not treat an open Configurator screen as SQL evidence.

Open questions

  • The generation algorithm and ownership of the 32-byte __configinfo service atom are unknown. Preservation is proven for the studied flow; generation is not.
  • Multi-part storage streams need a dedicated row-layout codec.
  • The extension protocol must be reproduced on another object class and a second platform build before being declared generally supported.
  • Configurators in-memory dirty-state implementation is inferred from behaviour, not decoded from platform source. Only the reload guidance is operationally relied upon.